Site assessment 5 min read Updated 2026-11-23

Is My Site Windy Enough? From an Airport Reading to Hub-Height Power Density

A farm at 300 m with a 4.8 m/s airport mean: scaling the wind to a 30 m and 50 m hub, correcting air density, and why the site moves from Class 1 to Class 3 on paper.

Most people who ask whether a small wind turbine makes sense start with one number: the average wind speed from the nearest airport or weather station. That number is real, but it was measured somewhere else, at a height that has nothing to do with your turbine, and it says nothing about how the wind is spread across the year. This guide turns that single reading into the figure that actually rates a site, the wind power density at hub height, using the calculators on this site and a worked example with real numbers.

The starting point

The example is a farm at 300 m elevation with a mean annual temperature of 15 °C. The nearest weather station, 12 km away on open ground, reports an annual mean wind speed of 4.8 m/s at the standard anemometer height of 10 m. The farm’s fields are bounded by hedges and scattered trees, and the owner is considering a turbine on a 30 m tower placed in the middle of a field, well clear of the farm buildings. Three corrections stand between the station number and a useful answer: height, density and distribution.

Step 1: scale the wind to hub height

Wind speed increases with height because the ground slows the air. The power law v₂ = v₁ × (h₂ ÷ h₁)^α describes this over open terrain, and farmland with hedges and scattered trees has a shear exponent α of about 0.20. In the wind shear calculator, 4.8 m/s at 10 m becomes 5.51 m/s at 20 m, 5.98 m/s at 30 m and 6.62 m/s at 50 m. The 30 m hub sees a speed 24.6% higher than the station, which is 1.93 times as much power in the wind. Before trusting this, check that the station terrain resembles yours. An airport sits on flat, mown grass; if you are confident only in the 1/7 law (α = 0.143) for the station itself, the 30 m estimate drops to 5.62 m/s. Use the lower figure as a cautious case.

Step 2: correct the air density

Power in the wind is proportional to air density, and density falls with elevation and temperature. In the wind power density calculator, 300 m and 15 °C give a pressure of about 978 hPa and a density of 1.182 kg/m³, 96.5% of the sea-level standard of 1.225 kg/m³. That 3.5% loss is small here, but at a 2,000 m mountain site with a 5 °C mean the density is 0.996 kg/m³, nearly a fifth lower, and it would deserve as much attention as the wind speed itself. Turbine power curves are quoted at 1.225 kg/m³, so remember this factor when you read them.

Step 3: account for the spread of wind speeds

The wind does not blow at its mean speed. Inland sites are well described by a Rayleigh distribution, under which the mean of v³ is 6/π, about 1.91, times the cube of the mean speed. The wind power density is therefore ½ρ × 1.91 × v̄³. For the farm the calculator gives:

  • at 10 m, 4.8 m/s: 125 W/m²;
  • at 30 m, 5.98 m/s: 241 W/m²;
  • at 50 m, 6.62 m/s: 328 W/m².

Had every hour blown at the mean speed, the 30 m figure would be about half as large. To see what this means for a machine, the turbine power calculator shows that a 3.5 m rotor with Cp 0.40 and a 90% drivetrain delivers 1,048 W at 8 m/s in this air; the site will see winds like that for a good share of the year, but far from all of it.

Step 4: read the class correctly

The NREL wind power classes are defined at 50 m above ground: Class 1 is below 200 W/m², Class 2 from 200 to 300, Class 3 from 300 to 400. The farm is Class 3, fair, at 50 m, with 328 W/m². Comparing the raw 10 m figure of 125 W/m² against the same table would have labelled it Class 1, poor, and probably ended the project on a false reading. With the cautious α = 0.143, the 50 m speed is 6.04 m/s and 249 W/m², Class 2. The honest summary is a Class 2 to 3 site: marginal to fair, worth a closer look if electricity is expensive, not a place to expect wind-farm economics.

Common mistakes

  • Comparing a 10 m station speed with a turbine power curve, which assumes hub-height wind.
  • Using α = 0.143 everywhere, which understates shear over hedges, woods and towns, or using a high α to make a weak site look good.
  • Placing the turbine near trees or buildings, where the air is slower and turbulent and no shear formula applies. Keep the rotor at least 10 m above anything within about 150 m.
  • Cubing the mean speed instead of using the distribution, which halves the power density.
  • Ignoring altitude: at 2,000 m and 5 °C the air is 18.7% thinner, so the same wind carries 18.7% less power than at sea level.

Checklist before you go further

  1. Find the station mean speed, its anemometer height and the terrain around it.
  2. Choose a shear exponent for your own terrain and scale to the planned hub height and to 50 m.
  3. Find the air density for your elevation and mean temperature.
  4. Compute the power density at hub height and at 50 m, and read the class at 50 m.
  5. Repeat with a cautious shear exponent and note the range.
  6. If the range straddles Class 2, consider a year of measurements with an anemometer at or near hub height before spending money on a tower.